Latest news: --- Porsche Piwis 42.950.025(Acronis Image) [2025] --- Land Rover & Jaguar IDS SDD v168 [2025] --- Pre- installed ODIS Service 25.0.3 and ODIS Engineering 19 [2025] --- Land Rover & Jaguar IDS SDD v166 [02.2025] --- MG SAIC Motor EPC [09.2025] --- VCDS v22.3.1 RUS [2022] --- Cummins INSITE 8.7.0.86 [2020] --- ODIS-E Flash files (Flashdaten) [10.2024] --- AUDI Flashdaten (flash disс) [22.05.2025] --- Chrysler ProQuest FCA EPC5 [09.2020] --- Renault CAN CLiP v231 [2023] --- MAN Mantis v.678 EPC [03.2022] --- Scania Multi [2403] 23.120.0.0 [03.2024] --- Scania Multi [2312] 23.120.0.0 [12.2023] --- IVECO Power Truck + Bus Q2 [07.2023] --- Mazda EPC II (EU) [02.2020] --- TOYOTA & LEXUS EPC ALL REGIONS [01.2025] --- Suzuki SDT-II Smart Diagnostic Tester v2.29.0.4 [2021] --- Renault CAN CLiP v222 [2022] --- Scania Multi [2203] 21.120.0.3 [03.2022] ---
  1. Smart Forum

  2. Facebook

  3. Auto-Software

  4. Auto-file.ORG

  5. EPC SOFTWARE

  6. Support US

Thread Rating:
  • 1 Vote(s) - 1 Average
  • 1
  • 2
  • 3
  • 4
  • 5
HYSTER Hypass Forklifts Spare Parts Catalog [01.2006]
#1
ZZ.Blank 
HYSTER Hypass Forklifts Spare Parts Catalog [01.2006]
Spare Parts Catalog for HYSTER Forklifts Equipments.

[Image: 01.png]
[Image: 02.png]
[Image: 03.png]
[Image: 04.png]
[Image: 05.png]
[Image: 06.png]
[Image: 07.png]

Quote:Region: Europe
Type: Parts Catalog
Languages: English, German
OS: Win2000, Win98, WinNT, WinXP ,WIN7,WIN8,WIN10
Quantity of DVD: 1 DVD  
Year: 2006
Date of update: 01/2006

Original spare parts catalog Hyster contains the spare parts catalogue of forklifts Hyster.
In catalog not present groups - Class2 Electric Motor Narrow Aisle Trucks and CLASS3 Electric Motor Hand Truck.


Code:
Hyster Hypass Parts & Service System.
The N-Compass Parts & Service system is designed to run on a standard 486DX or above PC with a CD-ROM Drive, 110 Meg of free Hard Disk Space, and 24 Meg of RAM running Windows 95. Due to the large number of graphics, it is recommended that the PC have a fast video card, local bus video is recommended. This release of NCompass TM is resolution independent. If your PC runs in 800x600 or 1024x768 256 color, you can run N-CompassTM in those resolutions. The startup screen will still appear in 640x480 but the parts pages and service pages will take advantage of the extra viewing
area.

Hyster Parts Manual
Parts manuals are accessed from the main screen by selecting a model series, a model and then a page from the Navigator. To return to the main screen anytime, click the Go to Main Screen
icon. If you were to select a model by clicking on the icon at the bottom of the main screen, followed by the model name, the system will launch the Navigator displaying available Parts Manual
Sections for that model.


Mega.NZ Links| Single Extraction | Real Screen Shots
Password: auto-epc.org


Attached Files
HYSTER Hypass Forklifts EPC [01.2006] MegaNZ Links.txt
File Type: .txt
Downloaded: 16 times
Size: 518 bytes

Installation Guide.txt
File Type: .txt
Downloaded: 55 times
Size: 919 bytes

Login Details.txt
File Type: .txt
Downloaded: 46 times
Size: 363 bytes

[Image: 02.png]
[Image: newfasl.gif] 
Hit the [Image: 00.png] buttons if this post help's you !!!
للراحه .... يمكنك التحدث معي بالعربيه

DONATE To Help with Monthly Server, Domain, and Service Costs

[Image: btn_donateCC_LG.gif]

[Image: donate-revolut.png]

Subscribe to our YOUTUBE channel

[Image: 152536647229623912.png]


[Image: dfj5za.gif] 
   Forum Management
[Image: 2qsb85t.png]
  Reply

#2
Hi all,
I have installed this on a Dell D630 machine with windows XP SP3, and followed the attached instructions. Does not want to start, gives the following error:
An error has occured in module in the routine PASSWORD.FRM, Form_Load
Error message:
Object required
Execution will now continue. Please call (770) 6505793.
Anyone has any ideas what's wrong? Do I have to run it in VMware?
I really need EPC this as i have to repair few hyster machine for a customer.
Thank you in advance!
  Reply
Thanks given by:

#3
Change your PC date to 2004
[Image: 02.png]
[Image: newfasl.gif] 
Hit the [Image: 00.png] buttons if this post help's you !!!
للراحه .... يمكنك التحدث معي بالعربيه

DONATE To Help with Monthly Server, Domain, and Service Costs

[Image: btn_donateCC_LG.gif]

[Image: donate-revolut.png]

Subscribe to our YOUTUBE channel

[Image: 152536647229623912.png]


[Image: dfj5za.gif] 
   Forum Management
[Image: 2qsb85t.png]
  Reply
Thanks given by:

#4
I have change it to 2004 when installing and when starting the program, but the same error. Is it maybe because I install it on a XP SP3 machine? should it be a simple XP machine?
I have noticed a thing: when installing, the installation slider goes up to 16% and then the installation finishes suddenly. It does not make a desktop icon as it says in installation guide, and in the add/remove programs section, it is just the name of the program, it does not show the size like other installed programs, so I think the installation process ends suddenly, without going through all process.
Any ideas?
Thanks a lot!
I made it work!
Here are the new instructions:

- HYSTER Hypass Forklifts Installation Guide :

- HYPASS work ONLY on Win98, win95,WinXP
- Set Your PC date back to 1998 .
- Mount the Image, copy the files from CD-ROM in another temporary location and double click "setup.exe". Do not change the installation path!
- After the installation is finished, just copy the folder named "System" from the installation location to folder to C:\MSI\Hyster\
- Go to "Start" >> "RUN" type "REGSVR32 C:\MSI\Hyster\System\Image95\IMGEDIT.OCX", without the quotes
- The PC Date must be in 1998 before you run the Program.
- Right click on the desktop icon "HYPASS", and edit the target to: "C:\MSI\Hyster\NCOMPASS.EXE" without quotes
- RUN the sotware from the desktop icon and FILL the information.
- Use this Login Details
* Serial: 115-2504-97848
* Password: FGY67630
- Leave the ISO image mounted in the virtual drive
- Enjoy Smile

****************************************
Please replace the old guide in the files if you think this is more accurate! Thanks!
  Reply
Thanks given by:

#5
Add-on:
While working with the program, it did not want to show pictures of the parts. It was asking for the path to the CD-ROM, in order to show the drawings with parts, but did not want to work that way. So, I copied the full content of the CD-ROM in a folder in the computer, and when the program asked for the "PARTS" folder, I pointed the way there. If nothing happens, just edit the file from"C:\MSI\HYSTER\NCOMPASS.INI" with the proper paths to files there.
Success!
  Reply
Thanks given by:

#6
One more add-on:
I have re-installed Hyster Hypass on another service laptop with Win XP SP3 as I did before, but this laptop had initially 2 GB of RAM. Everything went fine, but the program gave me the same error "out of memory...". I took out 1 GB of RAM of the computer and it works. This software cannot handle more than 1 GB of RAM.
  Reply
Thanks given by:

#7
link iso file dead can you reupload please.

DONATE To Help with Monthly Server, Domain, and Service Costs

[Image: wjb3g2.gif]
  Reply
Thanks given by:

#8
(12-25-2017, 10:12 AM)coshi Wrote: link iso file dead can you reupload please.

Post Updated with Mega.NZ Links
[Image: 02.png]
[Image: newfasl.gif] 
Hit the [Image: 00.png] buttons if this post help's you !!!
للراحه .... يمكنك التحدث معي بالعربيه

DONATE To Help with Monthly Server, Domain, and Service Costs

[Image: btn_donateCC_LG.gif]

[Image: donate-revolut.png]

Subscribe to our YOUTUBE channel

[Image: 152536647229623912.png]


[Image: dfj5za.gif] 
   Forum Management
[Image: 2qsb85t.png]
  Reply
Thanks given by:




Possibly Related Threads…
Thread Author Replies Views Last Post
ZZ.Blank HYSTER Hypass Parts Manual [2011] Admin 3 7,980 01-02-2019, 05:31 AM
Last Post: Admin
ZZ.Blank Hyster PC Service Tool v.3.0 [07.2006] Admin 0 13,171 03-13-2012, 06:39 AM
Last Post: Admin

Forum Jump:


Users browsing this thread:
1 Guest(s)

AUTO EPC

Welcome to Auto-EPC.org


  Register

AUTO-EPC.ORG